PULSE CONTROLLER

DESIGNED FOR OEM AND LABORATORY ULTRAFAST APPLICATIONS

PULSE CONTROLLER is a new dedicated system for laser process optimization through Pulse-to-Pulse Energy measurement of Fast and Ultrafast Lasers.

Unique in the market

Pulse Controller is developed on the top performance of Blink High Speed thermal sensor and modified HSM High Speed Meter (HSM-1000-PC).

Main features:

Detection of EVERY missing pulse when pulses have no sufficient energy to trigger the HSM meter.

Detection of EVERY low energy pulse when pulses have a detected energy below a user specified threshold.

Pulse Controller is based on Blink High Speed thermal sensor family working togheter with High speed Meter for real time Pulse Controllig (HSM-1000-PC).

times

Repetition rates

up to 0.8 MHz

power

Electronics

with sampling rate up to 500 Msample/s

active

Active area:

14x14mm

range

Wavelenght range:

Measures from 250nm to 1100nm and 10.6 microns

PULSE CONTROLLER for Real time Control of Ultrafast Laser Pulses (HSM-1000-PC)

THE ULTIMATE TECHNOLOGY

HSM-1000-PC is a High Speed Meter with dedicated “Pulse Controller” Software specifically developed to detect in real time any Laser Missing Pulse or any Laser Pulse below a user specified threshold. 

HSM-1000-PC can work according to three different modes; a “snapshot” modes, i.e. the “Oscilloscope Mode” allowing to display on the PC the acquired laser pulse traces (over 1 ms span).
In “real time” mode (“Real Time Parameters”) the user can monitor the behavior of main parameters of the acquired laser pulse train such as the average energy/pulse and average repetition rate (all those parameters integrated over 1 ms).

The two modes described above are, nevertheless, ancillary modes to the “Missing Pulses” mode, that is the main operation mode of the system that can perform the following 2 functions:

  • detection of every Missing Pulse, i.e. any laser pulse (or no pulse) that has not sufficient energy to trigger the acquisition (< “Trigger Start”) of the HSM Meter.
  • detection of every low energy pulse, i.e. pulse that has a detected energy below user specified threshold, “Threshold Low”

Trigger IN and Trigger OUT, SMA connectors, are available on HSM-1000-PC front panel.

The user can select between two kind of reference electrical signal input to the HSM-1000-PC Trigger IN, according to the operation mode of the Laser Under Test:

  • Sync signal: the HSM-1000-PC performs a comparison between a pulsed TTL electrical signal received by HSM-1000-PC @ Trigger IN from Laser Under Test and pulse detection by Blink HS sensor head.
  • Gate signal: the HSM-1000-PC performs a comparison between expected pulse train at pre-defined repetition rate and pulse detection by HS sensor head: the comparison starts at Gate signal high received by HSM-1000-PC @ Trigger IN and ends at Gate signal low received by HSM-1000-PC @ Trigger IN.

At Trigger OUT SMA connector a real time TTL alarm signal is delivered at the occurrence of any Missing Pulse or pulse whose energy is below user defined energy threshold, as shown in the following figure:

PULSE CONTROLLER - TRIGGER OUT SIGNAL

USER THRESHOLD AND TRIGGER OUT SIGNAL

Laser applications requiring high speed measurements can take advantage of the sub-microsecond response time; this BLINK HS feature allows to measure the energy of each pulse emitted by laser sources with repetition rates up to 1 MHz, pulse durations down to fs and average power up to 50W, characteristics that cannot be present all together in pyroelectric or photodiode sensors. Moreover, its high damage threshold and efficient water cooling allow to withstand energies up to 10mJ.

Pulse Controller can work together with any of the Blink High Speed Sensor.

PULSE CONTROLLER - High Sensitivity Version

THE ULTIMATE TECHNOLOGY

Pulse Controller is provided also as “High Sensitivity” Enhanced version able to measure Pulse Energy down to 0.25μJ.
Pulse Controller with Enhanced version is a measurement system made by the High Speed sensor Blink HS and HSM-1000-PC High Speed Meter. Such a low energy, combined with the high repetition rate, requires a dedicated and accurate calibration procedure, performed on the complete Pulse Controller Enhanced system.

注文コードパワー範囲エネルギー範囲Max Energy Density有用なアパーチャースペクトル範囲アブソーバ冷却
BM-A-5W-14-T-E-PC1 mW - 5W1 μJ – 2 mJ (*); 50 μJ -10 mJ (**)35 mJ/cm²14 x 14 mm0.2 – 11 µmTConvection見積もり
BM-A-8W-14-T-E-PC1 mW - 8W1 μJ – 2 mJ (*); 50 μJ -10 mJ (**)35 mJ/cm²14 x 14 mm0.2 – 11 µmTConvection見積もり
BM-A-15W-14-T-E-PC1 mW - 15W1 μJ – 2 mJ (*); 50 μJ -10 mJ (**)35 mJ/cm²14 x 14 mm0.2 – 11 µmTForced Air見積もり
BM-W-20W-14-T-E-PC1 mW - 20W1 μJ – 2 mJ (*); 50 μJ -10 mJ (**)35 mJ/cm²14 x 14 mm0.2 – 11 µmTWater見積もり
BM-A-5W-10-B-E-PC3 mW - 5 W3 μJ – 5 mJ (*); 100 μJ -20 mJ (**)120 mJ/cm210 x 10 mm0.5 – 1.1 µmBConvection見積もり
BM-A-10W-10-B-E-PC3 mW - 10 W3 μJ – 5 mJ (*); 100 μJ -20 mJ (**)120 mJ/cm210 x 10 mm0.5 – 1.1 µmBConvection見積もり
BM-A-25W-10-B-E-PC3 mW - 25 W3 μJ – 5 mJ (*); 100 μJ -20 mJ (**)120 mJ/cm210 x 10 mm0.5 – 1.1 µmBForced Air見積もり
BM-W-50W-10-B-E-PC3 mW - 50 W3 μJ – 5 mJ (*); 100 μJ -20 mJ (**)120 mJ/cm210 x 10 mm0.5 – 1.1 µmBWater見積もり
BM-A-5W-14-TX-E-PC1 mW - 5W0.25 μJ – 40 mJ (*); 20 μJ -1000 μJ (**)35 mJ/cm214 x 14 mm0.2 – 11 µmTConvection見積もり
BM-A-8W-14-TX-E-PC1 mW - 8W0.25 μJ – 40 mJ (*); 20 μJ -1000 μJ (**)35 mJ/cm214 x 14 mm0.2 – 11 µmTConvection見積もり
BM-A-15W-14-TX-E-PC1 mW - 15W0.25 μJ – 40 mJ (*); 20 μJ -1000 μJ (**)35 mJ/cm214 x 14 mm0.2 – 11 µmTForced Air見積もり
BM-W-20W-14-TX-E-PC1 mW - 20W0.25 μJ – 40 mJ (*); 20 μJ -1000 μJ (**)35 mJ/cm²14 x 14 mm0.2 – 11 µmTWater見積もり

(*): wavelength 1064nm, pulse duration < 10 ns
(**) wavelength 1064nm, pulse duration = 10 ms

BLINK HS

THE ULTIMATE TECHNOLOGY

BLINK HS patented technology, based on thermopile design, makes this product the fastest laser power and energy sensor currently available in the market. This technology allows to combine the high response speed of a photodiode with the broadband and high power operation of a thermopile.

Contact LaserPoint